Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WFML070A024B3 — OEM 1176919 with Bracket | Ships Today
ICP

ICP Hot Surface Igniter for WFML070A024B3 — OEM 1176919 with Bracket | Ships Today

SKU: 1183455 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface igniter assembly for the ICP / Heil / Tempstar / Comfortmaker WFML070A024B3 gas furnace, built around igniter part number 1176919 with its matching mounting bracket (1183455). The hot surface igniter (HSI) is the element that glows red-hot on a call for heat and lights the burners as the gas valve opens. HSIs are brittle and wear out from repeated thermal cycling — a cracked or aged element is the single most common cause of furnace no-heat calls. Replacing the igniter together with its bracket ensures correct positioning over the burner so ignition is reliable every cycle.

Specifications

Spec Value
Igniter Part Number 1176919
Bracket Part Number 1183455
Related Valve Reference 1176929 (HSI Snap WR 36J24618)
Type Hot Surface Igniter (HSI)
Brand ICP (Heil / Tempstar / Comfortmaker)
Fitment OEM Direct Replacement

Compatibility

Direct-fit replacement for the ICP/Heil/Tempstar WFML070A024B3 gas furnace and other ICP-family units using this HSI and bracket. The associated 36J24618-series snap-mount valve reference is listed for matching applications.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter. Shut off the gas supply.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and wiring before disconnecting.
  4. Remove — Unplug the igniter connector and unscrew the bracket. Handle the old igniter by its ceramic base only — never touch the element.
  5. Install — Mount the new igniter and bracket so the element sits correctly over the burner, then reconnect the harness. Do not touch the silicon-carbide element with bare fingers.
  6. Test — Restore power and gas, then run a heat cycle and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace runs the ignition sequence but never lights (no heat)
  • Igniter shows visible cracks, blistering, or no longer glows
  • Control board locks out after several failed ignition attempts
  • Open-circuit resistance reading across the igniter

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFML070A024B3 — OEM 1176919 with Bracket | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFML070A024B3 — OEM 1176919 with Bracket | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFML070A024B3 — OEM 1176919 with Bracket | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online