Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WFHR080B036A1 — HSI Kit | Ships Today
ICP

ICP Hot Surface Igniter for WFHR080B036A1 — HSI Kit | Ships Today

SKU: 1177210 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM hot surface igniter (part #1176919) with its mounting bracket (#1177210) for the ICP/Tempstar/Heil WFHR080B036A1 gas furnace. The hot surface igniter (HSI) glows red-hot when the control board energizes it at the start of a heat cycle, igniting the gas at the burners as the slow-opening gas valve (#1177204) lets fuel through. Igniters are the most frequently replaced furnace wear part — the heating element is brittle and degrades with every cycle until it cracks, develops a hairline break, or no longer reaches ignition temperature. The result is a furnace that runs the inducer, opens the valve, but never lights, then locks out.

Specifications

Spec Value
Part Number 1176919 (igniter), 1177210 (bracket)
Related Part 1177204 (slow-open HSI gas valve, 36J24510)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Voltage 120V
Application Gas Furnace Burner Ignition
Fitment OEM Replacement

Compatibility

Direct OEM replacement for the ICP WFHR080B036A1 furnace and matching Tempstar, Heil, and Comfortmaker models using a 120V hot surface ignition system. Confirm your furnace uses an HSI (not spark or direct ignition) before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter. Shut off the gas supply.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position, bracket alignment, and wire routing before removal.
  4. Remove — Unplug the igniter connector and remove the bracket screw. Handle the old igniter by the ceramic base only — never touch the element.
  5. Install — Mount the new igniter and bracket, set it to the factory gap/position from your photo, and reconnect the plug. Do not touch the new element with bare fingers; skin oils shorten its life.
  6. Test — Restore gas and power, then watch a full ignition cycle confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Igniter no longer glows during a heat call
  • Visible crack, hot spot, or broken element
  • Furnace locks out after the inducer runs but burners never light
  • Delayed ignition with a rumble or small puff at startup

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFHR080B036A1 — HSI Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFHR080B036A1 — HSI Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFHR080B036A1 — HSI Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online