Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WFHR060B024A1 — Furnace HSI | Ships Today
ICP

ICP Hot Surface Igniter for WFHR060B024A1 — Furnace HSI | Ships Today

SKU: 1177210 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter (part number 1176919) is the factory ignition source for the ICP / Tempstar / Heil WFHR060B024A1 furnace. On a heat call the control board energizes the igniter, which glows white-hot to light the gas burners. Igniters are the most common furnace failure point because the silicon-carbide or silicon-nitride element grows brittle with every heating cycle and eventually cracks or burns open. Typical symptoms are a furnace that clicks and runs the inducer but never lights, a glowing igniter that produces no flame, or a unit that locks out after several failed ignition attempts. Replacing the igniter restores reliable burner light-off. This listing also covers the matching igniter mounting bracket (1177210) so the new element seats in the correct position relative to the burners.

Specifications

Spec Value
Igniter Part Number 1176919
Bracket Part Number 1177210
Type Hot Surface Igniter (HSI)
Brand ICP (Tempstar / Heil / Comfortmaker)
Application Gas Furnace Burner Ignition
Fitment OEM Replacement

Compatibility

Built as the direct factory replacement for the ICP-family model WFHR060B024A1 and the broader line of ICP, Tempstar, Heil, and Comfortmaker gas furnaces that use this hot surface igniter and bracket assembly. Match the connector and mounting bracket to your original before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position and wire routing before removal.
  4. Remove — Unplug the igniter harness and unscrew the igniter/bracket from the burner assembly. Handle the new element by the ceramic base only — never touch the glow surface.
  5. Install — Mount the new igniter on its bracket, set the proper gap to the burner, and reconnect the harness.
  6. Test — Restore gas and power, then watch a full ignition cycle for a clean, immediate light.

Signs You Need a Replacement

  • Igniter glows but burners never light
  • No glow at all on a heat call
  • Visible crack, blister, or break in the element
  • Furnace locks out after repeated ignition retries

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFHR060B024A1 — Furnace HSI | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFHR060B024A1 — Furnace HSI | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFHR060B024A1 — Furnace HSI | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online