This OEM hot surface igniter (HSI) is the direct-fit ignition component for the ICP Tempstar/Heil WFEL070B036A1 gas furnace. The hot surface igniter is energized at the start of each heating cycle, glowing bright orange to ignite the gas as it leaves the burners. It operates on 120V line voltage and is the single most common cause of no-heat calls on this furnace platform. This listing covers the complete ignition group for the model, including OEM igniter 1176919, igniter bracket 1183455, and the matching HSI/valve assembly 36J24618 (OEM 1176929). When the igniter cracks, carbon-fouls, or loses its electrical path, the furnace will lock out and the control board will flash an ignition-failure fault code.

Specifications

Spec Value
Part Numbers 1176919 (igniter), 1183455 (bracket), 1176929 (HSI valve assy)
Type Hot Surface Igniter (HSI)
Brand ICP / Tempstar / Heil
Voltage 120V
Fit OEM Direct Replacement

Compatibility

Engineered for the ICP Tempstar/Heil WFEL070B036A1 70,000 BTU gas furnace and shared platform variants within the ICP family. Always confirm your existing igniter part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, shut off gas, and verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter wiring and bracket position before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift the old igniter and bracket clear of the burner. Handle the new ceramic element by the bracket only — never touch the silicon-carbon surface.
  5. Install — Mount the new igniter and bracket, reconnect the plug, and confirm proper gap and alignment over the burner.
  6. Test — Restore gas and power, start a heat call, and confirm the igniter glows and the burners light within the trial-for-ignition window.

Signs You Need a Replacement

  • Furnace blower runs but burners never light (no heat).
  • Igniter does not glow, or glows weak/uneven.
  • Visible cracks or white/gray fouling on the ceramic element.
  • Control board flashing an ignition-failure or lockout fault code.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFEL070B036A1 — Direct-Fit HSI Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFEL070B036A1 — Direct-Fit HSI Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFEL070B036A1 — Direct-Fit HSI Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online