Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for WFAR120D066B2 — OEM Kit with Bracket | Ships Today
ICP

ICP Hot Surface Igniter for WFAR120D066B2 — OEM Kit with Bracket | Ships Today

SKU: 1184324 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This hot surface igniter kit is the factory replacement for the ICP/Tempstar/Heil WFAR120D066B2 furnace and includes both the igniter (OEM part number 1176919) and its mounting bracket (OEM part number 1184324). The hot surface igniter glows red-hot when energized to ignite the burner gas on each heating cycle. Igniters are the single most common furnace failure — the silicon nitride or carbide element grows brittle with thousands of heat cycles and eventually cracks, leaving the furnace unable to light. When the igniter fails the furnace will draft and call for heat but never ignite, often locking out after several failed trial-for-ignition attempts. Installing the matched bracket ensures correct gap and alignment to the burner flame path.

Specifications

Spec Value
Igniter Part Number 1176919
Bracket Part Number 1184324
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Application Gas Furnace Ignition
Fits Model WFAR120D066B2

Compatibility

Engineered as the OEM replacement for the ICP/Tempstar/Heil WFAR120D066B2 furnace. The included bracket (1184324) matches the original mounting so the igniter sits at the correct depth and gap in the burner assembly. Confirm the connector style against your existing igniter before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and shut off the gas supply; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment door.
  3. Document — Photograph the igniter position, bracket orientation, and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector and unscrew the old igniter and bracket. Handle only by the ceramic base — never touch the element.
  5. Install — Mount the new igniter on its bracket, position it per your photo, and reconnect the harness without touching the element surface.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm the igniter glows and lights the burners.

Signs You Need a Replacement

  • Furnace drafts and clicks but never lights
  • Igniter does not glow when energized
  • Visible crack, blistering, or white residue on the element
  • Furnace locks out after repeated failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFAR120D066B2 — OEM Kit with Bracket | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFAR120D066B2 — OEM Kit with Bracket | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFAR120D066B2 — OEM Kit with Bracket | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online