This OEM hot surface igniter (HSI) kit replaces the original ignition components in your ICP Tempstar/Heil WFAR080C060B1 gas furnace. The kit includes OEM igniter 1176919 and its mounting bracket 1184324. The hot surface igniter glows red-hot at the start of each heating cycle to light the gas at the burners. Because it endures extreme thermal stress on every call for heat, the brittle silicon-carbide element is one of the most frequently replaced furnace parts. When it fails, the furnace will not produce heat — you will typically hear the inducer motor and gas valve attempt to fire, but no flame results. A cracked, pitted, or electrically open igniter is the most common cause of a no-heat furnace.

Specifications

Spec Value
OEM Part Number 1176919 (Igniter), 1184324 (Bracket)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Application Gas Furnace Ignition
Fits Model WFAR080C060B1
Kit Contents Igniter + Mounting Bracket

Compatibility

Engineered as a direct-fit replacement for the ICP Tempstar Heil WFAR080C060B1 gas furnace. These igniters are shared across many ICP-family (International Comfort Products) furnaces sold under the Tempstar, Heil, Comfortmaker, and Arcoaire brands. Always verify your existing part number against 1176919 before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power at the furnace switch and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter position and wiring connector before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift out the old igniter and bracket. Handle the new igniter by the bracket only — skin oils on the element cause premature failure.
  5. Install — Mount the new igniter and bracket in the same position, aligned over the burner, and reconnect the wiring per your photo.
  6. Test — Restore gas and power, then run a full heat cycle to confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • Furnace runs the inducer and clicks but never lights or produces heat
  • Igniter element is cracked, blistered, or no longer glows
  • Continuity test reads open (infinite resistance) across the igniter
  • Short cycling or intermittent ignition during cold weather

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP WFAR080C060B1 — Includes Igniter Bracket | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP WFAR080C060B1 — Includes Igniter Bracket | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP WFAR080C060B1 — Includes Igniter Bracket | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online