Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for VNK125N20B1 — Igniter/Sensor Kit | Ships Today
ICP

ICP Hot Surface Igniter for VNK125N20B1 — Igniter/Sensor Kit | Ships Today

SKU: 1009524 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM hot surface igniter and sensor service kit (part number 1009524) for the ICP/Tempstar/Heil VNK125N20B1 gas furnace. The hot surface igniter (HSI) glows red-hot when energized by the control board, lighting the gas at the burners on each call for heat, while the sensing function confirms flame so the gas valve stays open. A cracked, eroded, or contaminated igniter is among the most common causes of a furnace no-heat condition — the burners fail to light or the furnace locks out after repeated failed ignition attempts.

Specifications

Spec Value
Part Number 1009524
Type Hot Surface Igniter / Sensor Kit
Brand ICP (Tempstar / Heil)
Function Burner Ignition
Fitment OEM

Compatibility

Designed as the factory replacement igniter/sensor kit for the ICP/Tempstar/Heil VNK125N20B1 gas furnace and related Comfortmaker-family models. Confirm the igniter element shape and mounting bracket match your existing part before installing.

Installation Guide

  1. Safety First — Shut off the gas and disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter mounting position and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw(s); handle the old igniter by its ceramic base only. Never touch the new igniter element with bare fingers — skin oils cause premature failure.
  5. Install — Mount the new igniter so the element sits correctly in the burner flame path, then reconnect the wiring per your photo.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace blower runs but burners never ignite
  • Igniter does not glow on a call for heat
  • Visible cracks, chips, or white/gray erosion on the element
  • Furnace locks out after repeated failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP VNK125N20B1 — Igniter/Sensor Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP VNK125N20B1 — Igniter/Sensor Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP VNK125N20B1 — Igniter/Sensor Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online