Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for VNE050B12A1 — Silicon Nitride OEM Ignitor/Sensor Kit | Ships Today
ICP

ICP Hot Surface Igniter for VNE050B12A1 — Silicon Nitride OEM Ignitor/Sensor Kit | Ships Today

SKU: 1009524 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter kit (part number 1009524, IGNITOR/SENSOR HSP SK) is the factory ignition component for the ICP / Tempstar / Heil VNE050B12A1 gas furnace. The silicon nitride element heats to over 2,000°F to light the burners on each call for heat, while the matched flame sensor hardware verifies a stable flame. Over time an igniter can crack, blister, or become contaminated, leading to failed ignition, short-cycling, or control lockout and a cold home. Replacing it with the correct OEM igniter restores quick, reliable startup and prevents repeated failed-ignition lockouts at the furnace control.

Specifications

Spec Value
Part Number 1009524
Type Hot Surface Igniter / Sensor Kit (Silicon Nitride)
Brand ICP / Tempstar / Heil
Voltage 120V
Application Gas Furnace Ignition
Fits Model VNE050B12A1

Compatibility

Direct OEM replacement for the ICP VNE050B12A1 furnace. This igniter/sensor kit also services many ICP-family gas furnaces sold under the Tempstar, Heil, Comfortmaker, and related brands that originally shipped with part 1009524. Confirm your existing igniter part number before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power at the furnace switch and breaker. Verify zero voltage at the igniter leads with a multimeter.
  2. Access — Remove the furnace burner/blower service panel to expose the burner assembly.
  3. Document — Photograph the igniter wiring and mounting position before disconnecting.
  4. Remove — Unplug the connector, remove the mounting screw(s), and withdraw the old element. Handle the new igniter by its ceramic base only — never touch the silicon nitride element.
  5. Install — Mount the new igniter so the element seats correctly over the burner, secure the bracket screw, and reconnect the wiring per your photo.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and lights the burners within seconds with no lockout.

Signs You Need a Replacement

  • Furnace will not ignite or repeatedly locks out on failed ignition
  • Igniter does not glow, or glows weakly/unevenly during ignition
  • Visible cracks, chips, or white blistering on the igniter element
  • Short-cycling or intermittent no-heat calls in cold weather

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP VNE050B12A1 — Silicon Nitride OEM Ignitor/Sensor Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP VNE050B12A1 — Silicon Nitride OEM Ignitor/Sensor Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP VNE050B12A1 — Silicon Nitride OEM Ignitor/Sensor Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online