Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGX060KRCA0AAA — Silicon Nitride OEM 1171306 | Ships Today
ICP

ICP Hot Surface Igniter for RGX060KRCA0AAA — Silicon Nitride OEM 1171306 | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part number 1171306) is the factory ignition component for the ICP / Heil / Tempstar RGX060KRCA0AAA gas furnace. The igniter receives 120V from the furnace control board on each call for heat and glows to roughly 2,000°F to ignite the gas at the burners. Hot surface igniters are the most common failure point in a modern gas furnace — the brittle silicon nitride element cracks from thermal cycling, vibration, or even a fingerprint's oils. When it fails, the furnace draft inducer runs but the burners never light, leaving you with no heat and often a flashing fault code on the control board.

Specifications

Spec Value
Part Number 1171306
Type Hot Surface Igniter (Silicon Nitride)
Brand ICP / Heil / Tempstar
Voltage 120V
Application Gas Furnace Ignition
Fit OEM Direct Replacement

Compatibility

Engineered as the exact-fit replacement for the ICP / Heil / Tempstar / Comfortmaker RGX060KRCA0AAA gas furnace. The same igniter is used across many RGX-series and related Heil-built furnace platforms. Always confirm your part number against the failed igniter and bracket orientation before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, and shut off the gas. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter's bracket position and the wire/connector routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and withdraw the igniter carefully — never touch the ceramic element with bare fingers.
  5. Install — Mount the new igniter in the same orientation, reseat the screw, and reconnect the plug per your photo.
  6. Test — Restore gas and power, then run a heat call and confirm the igniter glows and the burners light within seconds.

Signs You Need a Replacement

  • Inducer runs but burners never ignite — no heat.
  • Visible crack, blister, or break in the ceramic element.
  • Igniter glows weakly or not at all on a heat call.
  • Control board flashes an ignition-failure or lockout fault code.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGX060KRCA0AAA — Silicon Nitride OEM 1171306 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGX060KRCA0AAA — Silicon Nitride OEM 1171306 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGX060KRCA0AAA — Silicon Nitride OEM 1171306 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online