Overview

This is the OEM hot surface igniter (Part No. 1171306) for the ICP / Heil / Tempstar RGX060KFXA0AAA gas furnace. The hot surface igniter (HSI) glows red-hot when the control board energizes it, igniting the gas at the burners during each heat cycle. Igniters are a normal wear item — the brittle silicon-carbide or nitride element degrades with every ignition cycle and eventually cracks or fails open. When the igniter fails you get a furnace that runs the inducer and clicks but never lights, a no-heat call, or a hard ignition lockout after several failed tries. A genuine OEM HSI restores fast, reliable burner ignition.

Specifications

Spec Value
Part Number 1171306
Description Ignitor (Hot Surface Igniter)
Type Hot Surface Igniter (HSI)
Brand ICP (Heil / Tempstar / Comfortmaker)
Fits Model RGX060KFXA0AAA
Application Gas Furnace Burner Ignition
Fitment OEM Direct Replacement

Compatibility

Direct OEM replacement igniter for the ICP / Heil / Tempstar RGX060KFXA0AAA gas furnace. Matches the factory mounting bracket and connector so it drops into the original location and seats over the burner exactly like the original. Handle only by the ceramic base — never touch the fragile element.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position and its wire harness routing before removal.
  4. Remove — Unplug the igniter connector, remove the mounting screw(s), and carefully withdraw the old igniter without touching the element.
  5. Install — Mount the new 1171306 igniter handling it only by the ceramic base, align it over the burner per your photo, and reconnect the harness.
  6. Test — Restore gas and power, start a heat call, and confirm the igniter glows and the burners light promptly with no lockout.

Signs You Need a Replacement

  • Furnace tries to start but burners never light (no heat)
  • Igniter does not glow when energized
  • Visible crack, break, or hot spot in the igniter element
  • Repeated ignition lockouts after several failed attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGX060KFXA0AAA Gas Furnace — OEM 1171306 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGX060KFXA0AAA Gas Furnace — OEM 1171306 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGX060KFXA0AAA Gas Furnace — OEM 1171306 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online