Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGX060KFCA0AAA Furnace — OEM Ignitor | Ships Today
ICP

ICP Hot Surface Igniter for RGX060KFCA0AAA Furnace — OEM Ignitor | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter (part 1171306) lights the burners on the ICP/Tempstar/Heil RGX060KFCA0AAA gas furnace. On a heat call the control board sends line voltage to the igniter, which glows white-hot and ignites the gas as the valve opens. The igniter element is fragile and degrades with every heating cycle — eventually it cracks or no longer reaches ignition temperature, leaving the furnace unable to light. A failed igniter is one of the most common causes of no-heat calls. Installing a fresh OEM ignitor restores fast, dependable burner light-off through the cold season.

Specifications

Spec Value
Part Number 1171306
Type Hot surface igniter (ignitor)
Brand ICP / Tempstar / Heil (OEM)
Application Gas furnace burner ignition
Fitment Direct OEM replacement

Compatibility

Designed for the ICP family RGX060KFCA0AAA 60,000 BTU gas furnace and related RGX-series furnaces specifying the 1171306 igniter, including matching Tempstar, Heil, and Comfortmaker models.

Installation Guide

  1. Safety First — Turn off gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment access panel.
  3. Document — Photograph the igniter bracket position and wire routing.
  4. Remove — Unplug the igniter connector and remove the mounting screw; handle the old element by the ceramic base only.
  5. Install — Mount the new igniter without touching the element, then reconnect the plug.
  6. Test — Restore gas and power and confirm the igniter glows and the burners light on a heat call.

Signs You Need a Replacement

  • Furnace blower runs but burners never ignite (no heat).
  • Igniter shows cracks or no longer glows.
  • Repeated lockouts after several ignition attempts.
  • Visible hot spots or a broken silicon carbide/nitride element.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGX060KFCA0AAA Furnace — OEM Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGX060KFCA0AAA Furnace — OEM Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGX060KFCA0AAA Furnace — OEM Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online