This is the genuine OEM hot surface igniter (part number 1171306) for the ICP / Heil / Tempstar RGX048KRCA0AAA gas furnace. The hot surface igniter is energized by the furnace control board at the start of each heat cycle; it glows to roughly 2,000°F to ignite the gas at the burners. Igniters are brittle and degrade with every cycle, eventually cracking or burning out — and a failed igniter is one of the most common causes of a furnace that blows cold air or locks out on ignition failure. This direct-fit OEM igniter restores fast, reliable lights and clears no-heat lockouts.

Specifications

Spec Value
OEM Part Number 1171306 (IGNITOR)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar / Comfortmaker
Voltage 120V
Fits Model RGX048KRCA0AAA
Fitment OEM Exact Replacement

Compatibility

Designed as a direct OEM replacement for the ICP-family gas furnace RGX048KRCA0AAA, also sold by Heil, Tempstar, and Comfortmaker on the International Comfort Products platform. Match the 1171306 part number and connector style to your existing igniter before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel to reach the igniter at the burner assembly.
  3. Document — Photograph the igniter bracket position and the plug connection before removing it.
  4. Remove — Unplug the igniter harness and remove the mounting screw(s). Handle only by the ceramic base — never touch the silicon-nitride/carbide element.
  5. Install — Mount the new igniter in the exact same position, ensuring the element sits in the burner flame path, and reconnect the plug.
  6. Test — Restore power, start a heat call, and confirm the igniter glows and lights the burners within the normal sequence.

Signs You Need a Replacement

  • Furnace blows cold air and never lights the burners.
  • Igniter does not glow during the ignition sequence.
  • Visible crack, blister, or break in the igniter element.
  • Furnace locks out on ignition failure after several attempts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGX048KRCA0AAA — OEM Part 1171306 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGX048KRCA0AAA — OEM Part 1171306 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGX048KRCA0AAA — OEM Part 1171306 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online