Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGX048KFCA0AAA — OEM Direct Fit | Ships Today
ICP

ICP Hot Surface Igniter for RGX048KFCA0AAA — OEM Direct Fit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part number 1171306) is the exact replacement for the ICP Tempstar Heil RGX048KFCA0AAA gas furnace. The hot surface igniter is the component that glows red-hot when the furnace receives a heat call, providing the ignition source that lights the burners. The control board sends line voltage to the igniter element; once it reaches operating temperature, the gas valve opens and the burners light. Because the element is repeatedly heated and cooled, it becomes brittle and eventually cracks or fails open — the single most common cause of no-heat calls in modern furnaces. Typical symptoms include a furnace that runs the inducer and blower but never lights, a glow that is weak or absent, or a visibly cracked igniter element. Handle the new igniter only by its ceramic base, never by the fragile element.

Specifications

Spec Value
OEM Part Number 1171306
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Function Burner Ignition
Mounting OEM Bracket / Direct Fit

Compatibility

Direct-fit OEM replacement for the ICP Tempstar Heil RGX048KFCA0AAA. This igniter is used throughout the ICP-family gas furnace lineup; confirm the bracket and connector match your existing igniter before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw, then withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter by its ceramic base, secure the screw, and reconnect the harness.
  6. Test — Restore power and verify the igniter glows and the burners light on a heat call.

Signs You Need a Replacement

  • Furnace runs but burners never ignite (no heat)
  • Igniter element is cracked, broken, or does not glow
  • Weak or partial glow during the ignition sequence
  • Repeated ignition lockouts on the control board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGX048KFCA0AAA — OEM Direct Fit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGX048KFCA0AAA — OEM Direct Fit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGX048KFCA0AAA — OEM Direct Fit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online