Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGX036KEXA0AAA — Furnace Ignitor | Ships Today
ICP

ICP Hot Surface Igniter for RGX036KEXA0AAA — Furnace Ignitor | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM hot surface igniter (part number 1171306) for the ICP/Heil/Tempstar RGX036KEXA0AAA gas furnace. The hot surface igniter is the component that glows orange-hot on a call for heat and lights the burners. The control board sends line voltage to the element, it heats to roughly 2000°F, and the gas valve opens to ignite the burners. Hot surface igniters are brittle and degrade with every heating cycle — the element thins, cracks, or breaks outright, which is the single most common reason a furnace ignites intermittently or fails to light at all. Replacing a worn or cracked igniter restores reliable first-try ignition and prevents nuisance lockouts on cold mornings.

Specifications

Spec Value
Part Number 1171306
Type Hot Surface Igniter
Brand ICP (Heil / Tempstar / Comfortmaker)
Application Gas Furnace Burner Ignition
Fitment OEM Replacement

Compatibility

Designed for the ICP/Heil/Tempstar RGX036KEXA0AAA gas furnace. OEM igniter 1171306 is used across many ICP-family RGX and N-series furnaces — match the part number and the mounting bracket orientation against your existing igniter before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position, bracket, and wire routing before removing anything.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and withdraw the old igniter. Never touch the new element with bare fingers — skin oils cause hot spots and early failure.
  5. Install — Mount the new igniter in the same position so the element sits correctly over the burner, then reconnect the harness.
  6. Test — Restore gas and power, start a heat cycle, and confirm the element glows and burners light on the first try.

Signs You Need a Replacement

  • Furnace clicks and tries to start but never lights
  • Visible crack, break, or white spots on the igniter element
  • Element no longer glows on a call for heat
  • Intermittent ignition or repeated ignition-failure lockouts

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGX036KEXA0AAA — Furnace Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGX036KEXA0AAA — Furnace Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGX036KEXA0AAA — Furnace Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online