ICP Hot Surface Igniter for RGS303LREA0AAAA — Electrode Ignitor | Ships Today
ICP

ICP Hot Surface Igniter for RGS303LREA0AAAA — Electrode Ignitor | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM igniter electrode (part number 1179966) is the hot surface ignition component for the ICP/Tempstar/Heil RGS303LREA0AAAA gas furnace. On each call for heat the control board sends voltage to the igniter, which heats to a glowing temperature in seconds and ignites the gas as the valve opens. Because the igniter element is brittle and cycles through extreme heat thousands of times per season, it is one of the most frequent furnace failure points. A cracked or worn igniter produces no heat surface, so the gas valve closes on a failed-ignition lockout and the furnace blows cold air or fails to light entirely. Installing a fresh OEM igniter restores fast, reliable ignition and prevents nuisance lockouts during the heating season.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter / Electrode
Brand ICP (Tempstar / Heil)
Function Furnace Ignition
Fitment OEM Replacement

Compatibility

Direct OEM fit for the ICP RGS303LREA0AAAA furnace and compatible Tempstar, Heil, and Comfortmaker models using the 1179966 igniter electrode. Verify the existing part number and bracket orientation before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/service panel to reach the ignition assembly.
  3. Document — Photograph the igniter position, bracket, and wire routing before removal.
  4. Remove — Unplug the igniter harness and remove the mounting screw, handling the old igniter by the ceramic base only.
  5. Install — Mount the new igniter without touching the element, then reconnect the harness.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace blows cold air or fails to light on a call for heat.
  • Visible crack, chip, or break in the igniter element.
  • Control board locks out after several failed ignition attempts.
  • Igniter no longer glows when energized.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS303LREA0AAAA — Electrode Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS303LREA0AAAA — Electrode Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS303LREA0AAAA — Electrode Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online