This OEM hot surface igniter (ignitor electrode, part number 1179966) is the ignition source for the ICP/Heil/Tempstar RGS303HSFA0AAAA gas furnace. When the thermostat calls for heat, the control board energizes this igniter, which glows red-hot to light the burners. As one of the highest-wear components in any furnace, the igniter is a leading cause of no-heat service calls. Its silicon-nitride/carbide element is brittle and degrades with every heating cycle until it can no longer reach ignition temperature. Common failure symptoms include the furnace blower running with no heat, a clicking control board that never lights the burners, or a visibly cracked or burned-out igniter element.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter / Ignitor Electrode
Brand ICP (Heil / Tempstar / Comfortmaker)
Voltage 120V
Fit OEM Direct Replacement

Compatibility

Engineered as a direct-fit replacement for the ICP/Heil/Tempstar/Comfortmaker RGS303HSFA0AAAA gas furnace. Always verify the OEM part number 1179966 against your existing igniter and mounting bracket before installation.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter wiring and bracket orientation before disconnecting.
  4. Remove — Unplug the igniter connector and unscrew the igniter from its mounting bracket. Handle only by the ceramic base — never touch the element.
  5. Install — Mount the new igniter, confirm proper alignment over the burner, and reconnect the harness per your photo.
  6. Test — Restore power and run a full heat cycle to confirm the igniter glows and lights the burners.

Signs You Need a Replacement

  • Furnace blower runs but produces no heat.
  • Igniter element is cracked, chipped, or shows burned-out spots.
  • Igniter no longer glows during a heat call.
  • Furnace locks out after repeated failed ignition attempts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS303HSFA0AAAA — OEM Ignitor Electrode 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS303HSFA0AAAA — OEM Ignitor Electrode 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS303HSFA0AAAA — OEM Ignitor Electrode 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online