Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS303HSAA0AAAA – Direct-Replacement Ignitor Electrode | Ships Today
ICP

ICP Hot Surface Igniter for RGS303HSAA0AAAA – Direct-Replacement Ignitor Electrode | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (ignitor electrode), part number 1179966, is the direct-replacement ignition component for the ICP / Tempstar / Heil RGS303HSAA0AAAA gas furnace. The igniter is energized at the start of each heat cycle, glowing red-hot to light the burner gas. It is one of the most common furnace failure points because the brittle silicon-carbide element degrades with every ignition cycle. Typical failure symptoms include the furnace blower running with no heat, the burners failing to light, repeated ignition lockouts (often shown as flashing LED fault codes on the control board), or a visibly cracked, pitted, or white-coated igniter tip. Replacing a worn igniter restores reliable, fast first-try ignition.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter / Ignitor Electrode
Brand ICP (Tempstar / Heil)
Voltage 120V
Application Gas Furnace Ignition
Fitment OEM Direct Replacement

Compatibility

Engineered for the ICP / Tempstar / Heil RGS303HSAA0AAAA gas furnace and other models in the same family that use OEM igniter 1179966. Always confirm your existing igniter part number and mounting bracket against the old unit before installing.

Installation Guide

  1. Safety First – Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access – Remove the furnace burner-compartment service panel.
  3. Document – Photograph the igniter wiring and bracket orientation before disconnecting.
  4. Remove – Unplug the igniter harness, remove the mounting screw, and carefully withdraw the old igniter without touching the element.
  5. Install – Mount the new igniter by the ceramic base only (never touch the silicon-carbide tip), secure the screw, and reconnect the harness per your photo.
  6. Test – Restore power and run a heat cycle; confirm the igniter glows and the burners light on first try.

Signs You Need a Replacement

  • Furnace blower runs but produces no heat.
  • Burners fail to light or light intermittently.
  • Repeated ignition lockouts or flashing control-board fault codes.
  • Visibly cracked, pitted, or white-coated igniter element.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS303HSAA0AAAA – Direct-Replacement Ignitor Electrode | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS303HSAA0AAAA – Direct-Replacement Ignitor Electrode | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS303HSAA0AAAA – Direct-Replacement Ignitor Electrode | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online