Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS303HEEA0AAAA — Ignitor Electrode | Ships Today
ICP

ICP Hot Surface Igniter for RGS303HEEA0AAAA — Ignitor Electrode | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM igniter electrode (part 1179966) is the component that lights the burners on the ICP / Tempstar / Heil RGS303HEEA0AAAA gas furnace. On each heat call the control board energizes the igniter, which glows red-hot to ignite the gas as the valve opens. Igniters are fragile and degrade with every cycle — they crack, develop hairline fractures, or simply burn out, leaving the furnace with no heat even though the inducer and gas valve are working. Replacing it with the correct OEM electrode restores dependable ignition and prevents repeated lockouts. Always handle the new igniter by its ceramic base, never the element, to avoid contaminating or cracking it.

Specifications

Spec Value
OEM Part Number 1179966
Type Hot Surface Igniter / Ignitor Electrode
Brand ICP / Tempstar / Heil
Application Gas Furnace Burner Ignition
Fitment OEM Direct Replacement

Compatibility

Direct-fit replacement for the ICP, Tempstar, Heil, and Comfortmaker RGS303HEEA0AAAA furnace and related RGS303 series models using the same igniter mount and connector. Confirm the bracket and plug style match your original before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position, bracket, and wire routing before removing.
  4. Remove — Unplug the igniter connector and remove the mounting screw, handling the old part by its base.
  5. Install — Mount the new igniter without touching the ceramic/element, then reconnect the plug per your photo.
  6. Test — Restore power, start a heat cycle, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • No heat — igniter does not glow on a heat call
  • Visible cracks, blisters, or breaks in the element
  • Furnace locks out after several failed ignition attempts
  • Igniter glows weakly or burners fail to light

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS303HEEA0AAAA — Ignitor Electrode | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS303HEEA0AAAA — Ignitor Electrode | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS303HEEA0AAAA — Ignitor Electrode | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online