Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS300LRAA0AAAA — OEM Electrode 1179966 | Ships Today
ICP

ICP Hot Surface Igniter for RGS300LRAA0AAAA — OEM Electrode 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (electrode assembly, part number 1179966) is the ignition source for the ICP Tempstar/Heil RGS300LRAA0AAAA gas furnace. On each call for heat, the furnace control board energizes the igniter, which glows white-hot to ignite the gas at the burners. A cracked, carbon-fouled, or open igniter is one of the most common causes of furnace no-heat lockouts. Symptoms of failure include the furnace failing to light, repeated ignition retries, a clicking gas valve with no flame, or the system locking out after several attempts. Because the igniter element is brittle silicon carbide or silicon nitride, it degrades with every heat cycle and is treated as a wear item.

Specifications

Spec Value
Part Number 1179966
Description Ignitor Electrode
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Fitment OEM
Application Gas Furnace Ignition

Compatibility

Engineered as the factory replacement igniter electrode for the ICP Tempstar/Heil RGS300LRAA0AAAA gas furnace. It also fits closely related RGS300 series models that share the same burner and ignition assembly. Always confirm your unit's model and serial tag matches before ordering.

Installation Guide

  1. Safety First — Disconnect electrical power at the furnace switch and breaker, and shut off the gas supply. Verify zero voltage with a multimeter before proceeding.
  2. Access — Remove the furnace burner compartment access panel.
  3. Document — Photograph the igniter bracket position and the wire harness routing before disconnecting anything.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and carefully withdraw the old igniter. Handle only by the ceramic base — never touch the fragile element.
  5. Install — Mount the new 1179966 igniter, align it to the burner per your photo, secure the screw, and reconnect the harness.
  6. Test — Restore gas and power, then run a heat cycle and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace will not ignite or produces no flame on a call for heat
  • Visible cracks, blisters, or carbon buildup on the igniter element
  • Repeated ignition retries followed by a lockout / blinking error code
  • Igniter fails to glow when commanded by the control board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS300LRAA0AAAA — OEM Electrode 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS300LRAA0AAAA — OEM Electrode 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS300LRAA0AAAA — OEM Electrode 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online