Overview

The OEM hot surface igniter (part number 1179966) is the ignition electrode for the ICP Tempstar Heil RGS243SEAA0AAAA gas furnace. When a call for heat is received, the control board energizes this igniter, which glows red-hot to ignite the gas at the burners. As the most heat-stressed component in the ignition sequence, igniters are a common wear item — repeated thermal cycling eventually cracks or weakens the element until it can no longer reach ignition temperature, leaving you with no heat. This is a genuine OEM ignitor electrode that matches the original specification for reliable, repeatable ignition.

Specifications

Spec Value
Part Number 1179966
Description Ignitor Electrode
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Fits Model RGS243SEAA0AAAA
Fit OEM Replacement

Compatibility

Engineered as a direct-fit replacement for the ICP Tempstar Heil RGS243SEAA0AAAA furnace and other ICP-family gas furnaces that specify OEM part 1179966. ICP, Tempstar, Heil, and Comfortmaker furnaces frequently share igniters across model lines. Confirm your unit calls for 1179966 before ordering to guarantee correct fitment.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, and shut off the gas. Verify zero voltage with a multimeter before proceeding.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter mounting and its wire harness/connector before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw(s). Handle by the ceramic base only — never touch the fragile element. Lift the old igniter out.
  5. Install — Seat the new igniter so the element sits in the correct burner ignition position, secure the screw(s), and reconnect the harness per your photo. Do not touch the element with bare fingers.
  6. Test — Restore gas and power, then start a heat cycle. Confirm the igniter glows, the burners light, and the flame proves.

Signs You Need a Replacement

  • Furnace will not light — no heat despite a call from the thermostat.
  • Igniter does not glow, or glows weakly/unevenly during the ignition sequence.
  • Visible cracks, blistering, or breaks in the igniter element.
  • Furnace tries to ignite, locks out, and repeats (failed ignition cycling).

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS243SEAA0AAAA — OEM 1179966 Ignitor Electrode | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS243SEAA0AAAA — OEM 1179966 Ignitor Electrode | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS243SEAA0AAAA — OEM 1179966 Ignitor Electrode | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.