Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS243LTAA0AAAA — Ignitor Electrode #1179966 | Ships Today
ICP

ICP Hot Surface Igniter for RGS243LTAA0AAAA — Ignitor Electrode #1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (ignitor electrode, part #1179966) is the direct ignition component for your ICP Tempstar Heil RGS243LTAA0AAAA gas furnace. On a call for heat, the furnace control energizes this igniter, heating its element until it glows hot enough to light the burner gas. Because the element is brittle and stressed on every heating cycle, it is one of the most common furnace failure points. Typical failure symptoms include no ignition, a furnace that clicks but never lights, a cracked or broken igniter, and a system that locks out after several failed ignition attempts.

Specifications

Spec Value
Part Number 1179966
Description Ignitor Electrode
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Application Gas Furnace Ignition
Fit OEM Direct Replacement

Compatibility

Engineered as a factory-correct replacement for the ICP Tempstar Heil RGS243LTAA0AAAA gas furnace and related ICP-family gas furnaces using the same ignition assembly. Always confirm your model and OEM part number (1179966) before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, and shut off the gas supply. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment service panel.
  3. Document — Photograph the igniter wiring and mounting orientation before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw(s); handle only by the ceramic base, never the fragile element.
  5. Install — Mount the new igniter without touching the element and reconnect the harness per your photo.
  6. Test — Restore gas and power, then run a heat cycle to confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace will not light or produce heat
  • Visible cracks, breaks, or burn-out on the igniter element
  • Repeated ignition lockouts after multiple failed attempts
  • No glow visible through the inspection port during a call for heat

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS243LTAA0AAAA — Ignitor Electrode #1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS243LTAA0AAAA — Ignitor Electrode #1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS243LTAA0AAAA — Ignitor Electrode #1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online