Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS243LSFA0AAAA — OEM Electrode 1179966 | Ships Today
ICP

ICP Hot Surface Igniter for RGS243LSFA0AAAA — OEM Electrode 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The OEM 1179966 ignitor electrode is the hot surface igniter for the ICP / Tempstar / Heil RGS243LSFA0AAAA gas furnace. On each heat call, the control board energizes the igniter and its element glows white-hot to light the burners. Hot surface igniters are brittle and have a finite number of cycles before the element cracks or burns through. A failed igniter is one of the most common no-heat causes: the furnace runs through its inducer and pre-purge but never lights, then locks out. Because the element is fragile, even a hairline crack from a bump or thermal stress can end its service life.

Specifications

Spec Value
Part Number 1179966 (IGNITOR ELECTRODE)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Voltage 120V
Application Gas Furnace Ignition
Fitment OEM Replacement

Compatibility

A direct OEM fit for the ICP RGS243LSFA0AAAA furnace and related ICP-family models originally equipped with igniter 1179966. Match the mounting bracket and connector against your existing igniter before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position and wiring before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw(s), and carefully withdraw the old element without touching the ceramic.
  5. Install — Mount the new 1179966 igniter — handling it only by the ceramic base — and reconnect the harness per your photos.
  6. Test — Restore power and start a heat cycle; confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace cycles but burners never light (no heat)
  • Visible crack or break in the igniter element
  • Igniter no longer glows during the ignition sequence
  • Repeated ignition lockouts on the control board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS243LSFA0AAAA — OEM Electrode 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS243LSFA0AAAA — OEM Electrode 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS243LSFA0AAAA — OEM Electrode 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online