Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS243LREA0AAAA — OEM Ignitor Electrode 1179966 | Ships Today
ICP

ICP Hot Surface Igniter for RGS243LREA0AAAA — OEM Ignitor Electrode 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM ignitor electrode (part number 1179966) for the ICP/Tempstar/Heil RGS243LREA0AAAA gas furnace. The igniter initiates combustion at the burners on every heating call — when energized by the control board it heats to the temperature needed to ignite the gas/air mixture. A failed igniter is among the most common causes of a no-heat furnace. Typical symptoms include the furnace cycling but never lighting, repeated ignition lockouts, a cracked or burned-out element, or an ignition-failure fault code on the control board. The element is brittle and can fail from age, thermal cycling, or a hairline crack that is only detectable by testing.

Specifications

Spec Value
Part Number 1179966
Description Ignitor Electrode
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Fit OEM Direct Replacement
Compatible Model RGS243LREA0AAAA
Application Gas Furnace Ignition

Compatibility

Engineered as a direct-fit OEM replacement for the ICP/Tempstar/Heil RGS243LREA0AAAA gas furnace. Because ICP manufactures under Tempstar, Heil, Comfortmaker, and Arcoaire labels on shared platforms, this igniter also services equivalent units. Always confirm part number 1179966 against your existing igniter before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, and shut off the gas supply. Verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter mounting and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw(s). Handle the old igniter only by its ceramic base — never touch the element.
  5. Install — Mount the new igniter without touching the silicon element with bare fingers, then reconnect the wiring per your photo.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • Furnace attempts ignition but burners never light
  • Repeated ignition lockout or board fault code
  • Visible crack, break, or burnout on the igniter element
  • No glow from the igniter during the ignition sequence

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS243LREA0AAAA — OEM Ignitor Electrode 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS243LREA0AAAA — OEM Ignitor Electrode 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS243LREA0AAAA — OEM Ignitor Electrode 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online