Overview

This is the genuine OEM ignitor electrode (ICP part number 1179966) for the ICP/Tempstar/Heil RGS240SSAA0AAAA gas furnace. The hot surface igniter heats to a glowing temperature on every call for heat and ignites the gas at the burners. Because it is cycled through intense heat repeatedly and is inherently fragile, it is among the most common furnace failure points. A cracked or worn-out igniter will not reach ignition temperature, so the furnace fails to light and the home loses heat. Watch for the blower running with no warm air, a furnace that locks out after several tries, or a visibly cracked igniter element.

Specifications

Spec Value
Part Number 1179966
Description Ignitor Electrode
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Fit OEM Direct Replacement
Application Gas Furnace Ignition

Compatibility

Engineered as a direct-fit replacement for the ICP/Tempstar/Heil RGS240SSAA0AAAA gas furnace. This igniter is shared across many ICP-family RGS-series furnaces — confirm OEM number 1179966 against your existing part for guaranteed fitment.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter and shut off the gas supply.
  2. Access — Remove the furnace burner/service panel.
  3. Document — Photograph the igniter wiring and bracket position before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw; withdraw the old element without touching the new element's surface.
  5. Install — Mount the new igniter, handling it only by the ceramic base, and reconnect the harness per your photo.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace blower runs but no ignition and no heat.
  • Furnace locks out after 3 failed ignition attempts.
  • Visible crack, blister, or break in the igniter element.
  • Igniter glows weakly or not at all on a call for heat.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240SSAA0AAAA — OEM 1179966 Ignitor Electrode | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240SSAA0AAAA — OEM 1179966 Ignitor Electrode | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240SSAA0AAAA — OEM 1179966 Ignitor Electrode | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online