Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS240SFAA0AAAA — OEM Electrode 1179966 | Ships Today
ICP

ICP Hot Surface Igniter for RGS240SFAA0AAAA — OEM Electrode 1179966 | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM ignitor electrode (part number 1179966) for the ICP / Tempstar / Heil RGS240SFAA0AAAA gas furnace. At the start of every heat cycle the control board energizes this hot surface igniter; it glows red-hot and lights the gas at the burners. Igniters are a wear item — the silicon nitride or carbide element becomes brittle with thousands of heat cycles and eventually cracks, develops hairline fractures, or fails to reach ignition temperature. The result is a furnace that clicks and tries to start but produces no heat, often locking out after several failed attempts.

Specifications

Spec Value
OEM Part Number 1179966 (Ignitor Electrode)
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Fits Model RGS240SFAA0AAAA
Application Gas furnace burner ignition
Fitment OEM direct replacement

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil RGS240SFAA0AAAA gas furnace. The 1179966 ignitor electrode services the matching furnace platforms across ICP's brand family (Heil, Tempstar, Comfortmaker, Arcoaire). Confirm the part number and mounting bracket style against your existing igniter before ordering, and handle the new element only by its ceramic base.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power; verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position, bracket, and wire routing before removal.
  4. Remove — Disconnect the igniter plug and remove the mounting screw; lift the old element out without touching the ceramic.
  5. Install — Mount the new 1179966 igniter (handle by the base only), set the gap/position per the original, and reconnect the plug.
  6. Test — Restore gas and power, run a heat call, and confirm the igniter glows and lights the burners on the first attempt.

Signs You Need a Replacement

  • Furnace attempts ignition but never lights, then locks out.
  • Igniter does not glow when the board calls for ignition.
  • Visible cracks, chips, or white spots on the element.
  • Intermittent no-heat that improves only after a reset.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240SFAA0AAAA — OEM Electrode 1179966 | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240SFAA0AAAA — OEM Electrode 1179966 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240SFAA0AAAA — OEM Electrode 1179966 | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online