Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS240SEEA0AAAA — Igniter Electrode | Ships Today
ICP

ICP Hot Surface Igniter for RGS240SEEA0AAAA — Igniter Electrode | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM hot surface igniter electrode (part number 1179966) is the ignition source for the ICP/Tempstar/Heil RGS240SEEA0AAAA gas furnace. On each call for heat the furnace control sends 120V to the igniter, which glows white-hot to light the burners. Hot surface igniters are brittle and degrade with every heating cycle — the element thins, cracks, and eventually fails open, leaving the furnace unable to light. Symptoms include no heat, the inducer running but burners never firing, or repeated ignition lockouts. Installing a fresh OEM igniter restores fast, reliable burner ignition and prevents the cold-house no-heat calls that define a failed element.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter Electrode
Brand ICP / Tempstar / Heil
Operating Voltage 120V
Fits Model RGS240SEEA0AAAA

Compatibility

Designed for the ICP RGS240SEEA0AAAA and shared across many ICP-family gas furnaces (Tempstar, Heil, Comfortmaker, Arcoaire). Confirm your furnace uses a hot surface igniter (not a spark or pilot system) before ordering — this is a direct OEM replacement.

Installation Guide

  1. Safety First — Shut off gas and disconnect electrical power, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment door.
  3. Document — Photograph the igniter bracket position and wiring connector before disconnecting.
  4. Remove — Unplug the igniter harness and remove the mounting screw; handle only by the ceramic base, never the element.
  5. Install — Seat the new igniter, secure the screw, and reconnect the harness — do not touch the glow element with bare fingers.
  6. Test — Restore gas and power, call for heat, and verify the igniter glows and burners light.

Signs You Need a Replacement

  • No heat — burners never ignite
  • Inducer runs but furnace locks out after several tries
  • Igniter does not glow when a heat cycle starts
  • Visible cracks, blistering, or breaks in the element

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240SEEA0AAAA — Igniter Electrode | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240SEEA0AAAA — Igniter Electrode | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240SEEA0AAAA — Igniter Electrode | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online