Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS240LFFA0AAAA – Electrode Ignitor | Ships Today
ICP

ICP Hot Surface Igniter for RGS240LFFA0AAAA – Electrode Ignitor | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM ICP hot surface igniter (part #1179966) is the electrode that lights your gas furnace. On each call for heat, the control board sends voltage to the igniter, which glows red-hot and ignites the gas at the burners. Hot surface igniters are brittle and degrade over time from repeated thermal cycling, making them one of the most frequent no-heat failure points. Common symptoms include a furnace that clicks and tries to start but never lights, a cracked or visibly white/blistered igniter element, short-cycling on ignition lockout, or an igniter that no longer glows when energized.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter / Electrode
Brand ICP (Tempstar / Heil / Comfortmaker)
Application Gas Furnace Ignition
Fit OEM Replacement

Compatibility

This igniter is the factory-specified replacement for the ICP/Tempstar/Heil gas furnace model RGS240LFFA0AAAA. It also fits many ICP-family furnaces that use this electrode-style hot surface igniter. Confirm the mounting bracket and connector match your existing igniter before installing.

Installation Guide

  1. Safety First – Shut off the furnace power switch and the gas supply, then verify zero voltage with a multimeter before touching the igniter.
  2. Access – Remove the furnace burner compartment door.
  3. Document – Photograph the igniter position and wiring connector before removal.
  4. Remove – Unplug the igniter harness and remove the mounting screw(s). Handle the old element by the ceramic base only.
  5. Install – Mount the new igniter without touching the element with bare fingers (oils shorten its life), then reconnect the harness.
  6. Test – Restore gas and power, call for heat, and confirm the igniter glows and lights the burners promptly.

Signs You Need a Replacement

  • Furnace attempts ignition but never lights
  • Igniter does not glow when energized
  • Visible cracks, blisters, or white spots on the element
  • Repeated ignition lockouts or short-cycling

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240LFFA0AAAA – Electrode Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240LFFA0AAAA – Electrode Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240LFFA0AAAA – Electrode Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online