This is the genuine OEM hot surface igniter electrode (part 1179966) for the ICP / Heil / Tempstar RGS240HTEA0AAAA gas furnace. On a call for heat, the control board energizes the igniter, which glows white-hot to ignite the gas at the burners during the ignition sequence. Hot surface igniters are brittle silicon-carbide or silicon-nitride elements that degrade with every heating cycle and eventually crack, develop hairline fractures, or simply stop glowing. A failed igniter is the single most common cause of a no-heat furnace: the inducer runs, the gas valve waits, but ignition never occurs and the board locks out. Because the element is fragile, it should never be touched on the glow surface during installation — skin oils shorten its life dramatically.

Specifications

Spec Value
OEM Part Number 1179966
Type Hot Surface Igniter Electrode
Brand ICP / Heil / Tempstar
Function Burner Ignition
Fitment OEM Direct Replacement

Compatibility

Direct-fit replacement igniter for the ICP RGS240HTEA0AAAA gas furnace and related Heil, Tempstar, and Comfortmaker platform models. Confirm the mounting bracket and connector match your existing igniter before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and connector routing before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw, handling the element only by its ceramic base.
  5. Install — Mount the new igniter without touching the glow element, then reconnect the plug per your photo.
  6. Test — Restore power and watch a full ignition cycle to confirm the igniter glows and the burners light.

Signs You Need a Replacement

  • Furnace runs the inducer but never ignites
  • Igniter does not glow during the heat sequence
  • Visible cracks, breaks, or white powder on the element
  • Control board locks out on ignition failure

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240HTEA0AAAA — Direct-Fit Electrode | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240HTEA0AAAA — Direct-Fit Electrode | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240HTEA0AAAA — Direct-Fit Electrode | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.