Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS240HSFA0AAAA — Ignitor Electrode | Ships Today
ICP

ICP Hot Surface Igniter for RGS240HSFA0AAAA — Ignitor Electrode | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM hot surface ignitor electrode (OEM 1179966) for the ICP / Tempstar / Heil RGS240HSFA0AAAA. The hot surface igniter glows red-hot when energized to ignite the gas at the burners during each heating cycle. It is one of the most frequently replaced furnace components because the brittle silicon-carbide or silicon-nitride element degrades with every ignition cycle and eventually cracks. When the igniter fails, the furnace draws inducer and gas-valve sequence but never lights, often locking out after several failed trials.

Specifications

Spec Value
OEM Part Number 1179966 (Ignitor Electrode)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Function Burner Ignition
Mounting OEM bracket / direct-fit

Compatibility

Designed for the ICP RGS240HSFA0AAAA and shared across many ICP-family packaged gas/electric and furnace platforms branded Tempstar, Heil, Comfortmaker, and Arcoaire. Confirm the OEM number and mounting bracket against your existing igniter before installing.

Installation Guide

  1. Safety First — Shut off gas, disconnect power, and verify zero voltage with a multimeter.
  2. Access — Remove the burner/control compartment panel.
  3. Document — Photograph the igniter position and wiring before disconnecting.
  4. Remove — Unplug the igniter connector and remove the mounting screw; handle the old element by the bracket only.
  5. Install — Mount the new igniter without touching the ceramic element, then reconnect per your photo.
  6. Test — Restore gas and power and confirm the igniter glows and lights the burners on a heat call.

Signs You Need a Replacement

  • Furnace runs the inducer but the burners never ignite
  • Igniter does not glow when energized
  • Visible cracks or breaks in the ceramic element
  • Repeated ignition lockouts after several trials

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240HSFA0AAAA — Ignitor Electrode | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240HSFA0AAAA — Ignitor Electrode | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240HSFA0AAAA — Ignitor Electrode | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online