Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS240HRFA0AAAA — Electrode | Ships Today
ICP

ICP Hot Surface Igniter for RGS240HRFA0AAAA — Electrode | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM igniter electrode (part 1179966) is the hot surface ignition source for your ICP / Tempstar / Heil RGS240HRFA0AAAA gas furnace. On each call for heat, line voltage energizes the igniter element until it glows orange-hot, lighting the burners as the gas valve opens. Hot surface igniters are the single most common furnace failure point — the brittle silicon-carbide or silicon-nitride element cracks from thermal cycling, leaving you with a furnace that goes through its sequence but never lights. A no-heat call, a furnace that ignites on the second or third try, or a visibly cracked element all point to a failed igniter. Replacing with the correct OEM electrode restores fast, dependable ignition.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter Electrode
Brand ICP (Tempstar / Heil)
Voltage 120V
Application Gas Furnace Ignition

Compatibility

Direct OEM fit for the ICP RGS240HRFA0AAAA furnace and related Tempstar, Heil, Comfortmaker, and Arcoaire RGS-series furnaces using the same burner and ignition assembly. Verify the part number on your existing igniter before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter mounting and wire routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw(s), and withdraw the element — handle by the ceramic base only.
  5. Install — Seat the new igniter without touching the element, reattach the screw and connector per your photo.
  6. Test — Restore power and confirm the igniter glows and lights the burners on the first call.

Signs You Need a Replacement

  • No heat — furnace sequences but never lights.
  • Visible crack or break in the igniter element.
  • Igniter no longer glows orange during the heat call.
  • Repeated ignition lockout / multiple ignition attempts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS240HRFA0AAAA — Electrode | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS240HRFA0AAAA — Electrode | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS240HRFA0AAAA — Electrode | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online