Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS214HRAA0AAAA — OEM Furnace Ignitor | Ships Today
ICP

ICP Hot Surface Igniter for RGS214HRAA0AAAA — OEM Furnace Ignitor | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (electrode), part 1179966, is the component that glows red-hot to light the burners on the ICP / Heil / Tempstar RGS214HRAA0AAAA gas furnace. On a call for heat, the control board sends 120V to the igniter; once it reaches ignition temperature, the gas valve opens and the burners light. Igniters are the most frequently replaced furnace part because the silicon-carbide/nitride element is brittle and degrades with every heating cycle. A failed igniter is the number-one cause of a furnace that tries to start but never produces heat.

Specifications

Spec Value
Part Number 1179966
Type Hot surface igniter / ignitor electrode
Brand ICP / Heil / Tempstar
Voltage 120V
Function Direct burner ignition

Compatibility

Designed for the ICP/Heil/Tempstar RGS214HRAA0AAAA furnace and shared-platform models from Comfortmaker, Day & Night, and Arcoaire that use this igniter assembly. Match the mounting bracket and connector to your existing igniter before installing.

Installation Guide

  1. Safety First — Shut off power at the furnace switch and breaker; verify zero voltage with a multimeter. Shut off the gas.
  2. Access — Remove the furnace burner/blower service panel.
  3. Document — Photograph the igniter position and wiring connector.
  4. Remove — Unplug the connector and remove the mounting screw. Handle only by the ceramic base — never touch the element.
  5. Install — Mount the new igniter, taking care not to bump the fragile element, and reconnect the plug.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm the burners light.

Signs You Need a Replacement

  • Furnace ignites with no flame, then locks out
  • Igniter does not glow on a call for heat
  • Visible cracks, blistering, or white powder on the element
  • Repeated short-cycling on the ignition sequence

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS214HRAA0AAAA — OEM Furnace Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS214HRAA0AAAA — OEM Furnace Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS214HRAA0AAAA — OEM Furnace Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online