This OEM igniter electrode (P/N 1179966) is the component that lights the burners on your ICP / Tempstar / Heil RGS213SSEA0AAAA gas furnace. On each call for heat the control board sends voltage to the igniter, which heats to a glowing temperature and ignites the gas as it leaves the burners. Hot surface igniters are brittle and degrade with every heat cycle, making them one of the most frequent no-heat failures. Common symptoms include a furnace that clicks and tries to start but never lights, a cracked or visibly eroded igniter element, or short-cycling on ignition lockout after several failed attempts.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter / Ignitor Electrode
Brand ICP (Tempstar / Heil)
Application Gas Furnace Burner Ignition
Fit Direct OEM Replacement

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil RGS213SSEA0AAAA and other RGS213-series furnaces specifying igniter electrode part number 1179966.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/service panel to reach the ignition assembly.
  3. Document — Photograph the igniter's wiring and mounting orientation before removal.
  4. Remove — Unplug the igniter harness and remove the mounting screw(s). Handle only by the ceramic base — never touch the silicon nitride/carbide element.
  5. Install — Mount the new igniter in the same position, ensuring it sits correctly in the burner flame path, then reconnect the harness.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and lights the burners on the first cycle.

Signs You Need a Replacement

  • Furnace attempts ignition but never lights (no flame).
  • Visible crack, fracture, or heavy erosion on the igniter element.
  • Repeated ignition lockouts or short-cycling on startup.
  • Igniter no longer glows when the unit calls for heat.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS213SSEA0AAAA — OEM Electrode | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS213SSEA0AAAA — OEM Electrode | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS213SSEA0AAAA — OEM Electrode | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online