Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS181HDAA0AGAA — Ignitor Electrode | Ships Today
ICP

ICP Hot Surface Igniter for RGS181HDAA0AGAA — Ignitor Electrode | Ships Today

SKU: 1179966 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter electrode (part 1179966) is the ignition source for the gas heat section of the ICP/Tempstar/Heil RGS181HDAA0AGAA packaged unit. On a heat call, the control board sends voltage to the igniter, which glows red-hot to light the burners. Igniters are a wear item — repeated heating and cooling cycles eventually crack the element, leaving the furnace unable to light. A no-heat call that ends in lockout is very often a failed igniter.

Specifications

Spec Value
Part Number 1179966
Type Hot Surface Igniter / Ignitor Electrode
Brand ICP / Tempstar / Heil
Function Burner Ignition
Fit OEM

Compatibility

Direct fit for the ICP RGS181HDAA0AGAA packaged gas/electric unit and other Tempstar, Heil, and Comfortmaker furnaces and packaged units using the same ignition assembly. Handle the element only by the ceramic base — skin oils shorten igniter life.

Installation Guide

  1. Safety First — Shut off gas and disconnect power; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter mounting and wire routing before removal.
  4. Remove — Unplug the igniter connector and remove the mounting screw(s); discard the cracked element.
  5. Install — Mount the new igniter without touching the element, reconnect the harness.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and burners light.

Signs You Need a Replacement

  • No heat / furnace locks out after several ignition attempts
  • Igniter no longer glows on a heat call
  • Visible crack or break in the ceramic element
  • Open circuit / no continuity when tested with a meter

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS181HDAA0AGAA — Ignitor Electrode | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS181HDAA0AGAA — Ignitor Electrode | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS181HDAA0AGAA — Ignitor Electrode | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online