This is the OEM igniter (part number 1184216, IGNITOR SPARKER) for the ICP Tempstar Heil RGS180STAA0AAAA gas furnace. The igniter is responsible for lighting the burners on each call for heat. When the thermostat signals the control board, the igniter heats up (or sparks) to ignite the gas at the burner assembly. A cracked, weakened, or burned-out igniter is one of the most common causes of furnace no-heat calls. Typical failure symptoms include the furnace cycling on the blower but producing no flame, repeated ignition lockouts, or a visibly cracked igniter element.

Specifications

Spec Value
Part Number 1184216
Description Ignitor Sparker
Type Furnace Igniter
Brand ICP (Tempstar / Heil)
Fits Model RGS180STAA0AAAA
Fitment OEM Direct Replacement

Compatibility

This igniter is a direct OEM replacement for the ICP Tempstar Heil RGS180STAA0AAAA furnace. ICP manufactures equipment under several brand names including Tempstar, Heil, and Comfortmaker, so this part may also fit equivalent models across those lines. Always verify the part number against your old igniter before installing.

Installation Guide

  1. Safety First – Disconnect power to the furnace at the service switch or breaker and verify zero voltage with a multimeter.
  2. Access – Remove the furnace burner compartment access panel.
  3. Document – Take a photo of the igniter wiring and mounting position before disconnecting anything.
  4. Remove – Unplug the igniter wire harness and remove the mounting screw(s); carefully withdraw the old igniter, handling it only by the ceramic base.
  5. Install – Mount the new igniter using the original screw(s), being careful not to touch the element with bare fingers, and reconnect the wire harness per your photo.
  6. Test – Restore power and run a heat cycle, confirming the igniter glows/sparks and the burners light cleanly.

Signs You Need a Replacement

  • Furnace runs the inducer and blower but never lights the burners.
  • Repeated ignition lockout codes on the control board.
  • Visible cracks, hot spots, or breaks in the igniter element.
  • Igniter does not glow or spark on a call for heat.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS180STAA0AAAA – Sparker Ignitor | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS180STAA0AAAA – Sparker Ignitor | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS180STAA0AAAA – Sparker Ignitor | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online