Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS150SEAB0AGAA — Igniter & Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS150SEAB0AGAA — Igniter & Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface igniter for the ICP/Heil/Tempstar RGS150SEAB0AGAA gas furnace, supplied with the matching igniter wiring harness kit. The igniter (OEM 1171306) is a 120-volt silicon-carbide/nitride element that glows red-hot on a call for heat to ignite the burner gas. The included wiring kit (OEM 1188370) provides the correct connector and lead so the new igniter mates cleanly to the furnace control board. A cracked or worn igniter is one of the single most common causes of no-heat furnace failures — when it fails you typically get a furnace that runs the inducer and opens the gas valve but never lights, or short-cycles on ignition lockout.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter (HSI)
Brand ICP / Heil / Tempstar / Comfortmaker
Voltage 120V
Fitment OEM direct replacement

Compatibility

Engineered for the ICP RGS150SEAB0AGAA 150,000 BTU gas furnace and the family of Heil, Tempstar, and Comfortmaker furnaces that share this ignition system. Always confirm your part number against the unit before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and shut off the gas. Verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter mounting and wiring routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw, and lift out the old igniter. Handle the new element by its ceramic base only — skin oils cause hot-spot failure.
  5. Install — Mount the new igniter so the element sits correctly in the burner flame path, then connect the new wiring kit per your photo.
  6. Test — Restore gas and power and watch a full ignition cycle to confirm a clean, immediate light.

Signs You Need a Replacement

  • Furnace ignites the inducer and gas valve but never lights the burners.
  • Visible cracks, blistering, or white spots on the igniter element.
  • Repeated ignition lockout codes or no-heat short cycling.
  • Igniter glows weakly or not at all on a heat call.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150SEAB0AGAA — Igniter & Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150SEAB0AGAA — Igniter & Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150SEAB0AGAA — Igniter & Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online