Overview

This is the genuine OEM hot surface igniter (HSI) for the ICP / Tempstar / Heil RGS150SEAA0AKAA gas furnace. The igniter is the component that glows red-hot on a call for heat and lights the burner gas. The kit covers OEM part number 1171306 (igniter) plus 1188370 (igniter wiring kit) so you have the matching harness for a clean install. Hot surface igniters are brittle silicon-carbide or silicon-nitride elements that degrade over thousands of heating cycles. Common failure symptoms include no ignition, delayed ignition with a small "whoomp," the furnace locking out after several trial-for-ignition attempts, and a visible crack or no glow when the element is energized.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter (HSI)
Brand ICP / Tempstar / Heil
Application Gas furnace burner ignition
Includes Igniter + wiring harness kit
Fitment OEM replacement

Compatibility

Direct-fit replacement for the ICP RGS150SEAA0AKAA gas furnace and shared chassis under the Tempstar, Heil, and Comfortmaker brands that use the same ignition assembly. Always confirm your existing igniter part number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, shut off the gas, and verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment door.
  3. Document — Photograph the igniter mounting and wiring before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw(s), and withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter (handle only by the ceramic base), route and connect the new wiring kit per your photo.
  6. Test — Restore gas and power, run a heat cycle, and confirm the element glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace blower runs but no flame and no heat.
  • Repeated ignition lockouts after 3–4 trial attempts.
  • No visible glow when the igniter is energized.
  • Cracked, chipped, or whitened igniter element.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150SEAA0AKAA — Furnace Ignitor with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150SEAA0AKAA — Furnace Ignitor with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150SEAA0AKAA — Furnace Ignitor with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart