Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS150LEAA0AKAA — Includes Igniter Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS150LEAA0AKAA — Includes Igniter Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM hot surface igniter assembly for the ICP / Tempstar / Heil RGS150LEAA0AKAA gas furnace. The hot surface igniter (OEM 1171306) glows red-hot on a heat call to ignite the gas at the burners, and this listing also includes the matching igniter wiring kit (OEM 1188370) so the connector and harness can be replaced together. Hot surface igniters are a common wear item — repeated heating and cooling cycles eventually crack the brittle element. Typical failure symptoms include no ignition on a heat call, the furnace locking out after several failed light attempts, a clicking gas valve with no flame, or an igniter that no longer glows. Handle the igniter only by the ceramic base and never touch the glow surface with bare fingers.

Specifications

Spec Value
OEM Part Number 1171306 (Igniter), 1188370 (Wiring Kit)
Part Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Operating Voltage 120V
Application Gas Furnace Ignition
Fits Model RGS150LEAA0AKAA

Compatibility

This igniter and wiring kit are a direct OEM fit for the ICP-built RGS150LEAA0AKAA and the equivalent Tempstar, Heil, and Comfortmaker variants that share the same furnace platform. Always confirm your OEM part number against the unit's service label before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, and shut off the gas. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/control access panel.
  3. Document — Photograph the igniter mounting and wiring connector before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw(s), and carefully withdraw the old igniter without touching the element.
  5. Install — Mount the new igniter in the same position, route the new wiring kit, and reconnect to the control board per your photo.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace fails to ignite or locks out after multiple attempts.
  • Igniter no longer glows or glows weakly/unevenly.
  • Visible cracks or hot spots on the igniter element.
  • Brittle or burnt igniter wiring/connector.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150LEAA0AKAA — Includes Igniter Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150LEAA0AKAA — Includes Igniter Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150LEAA0AKAA — Includes Igniter Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online