Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS150LDBA0AGAA — OEM 1171306 + Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS150LDBA0AGAA — OEM 1171306 + Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM hot surface igniter (part number 1171306) with its matching wiring kit (part number 1188370) for the ICP / Tempstar / Heil RGS150LDBA0AGAA gas furnace. On each call for heat, the control board energizes the igniter; it glows white-hot and ignites the gas at the burners. Hot surface igniters are brittle and wear out — micro-cracks, contamination from oils, and thermal cycling eventually cause an open element. The result is a furnace that runs the inducer and gas valve but never lights, locks out, and leaves you with no heat. Installing a fresh igniter and the correct wiring harness restores reliable ignition. Always handle the new igniter by its ceramic base — never touch the silicon-carbide element.

Specifications

Spec Value
Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Element Silicon carbide
Brand ICP / Tempstar / Heil
Fits Model RGS150LDBA0AGAA
Application Gas furnace ignition

Compatibility

Built for the ICP RGS150LDBA0AGAA and shared-platform Tempstar, Heil, Comfortmaker, and Day & Night gas furnaces using this igniter and harness. The included wiring kit (1188370) ensures a clean, correct connection to the furnace harness. Verify your model on the rating plate before ordering.

Installation Guide

  1. Safety First — Turn off gas and disconnect power. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment door to expose the igniter near the burners.
  3. Document — Photograph the igniter position and harness routing before disconnecting.
  4. Remove — Unplug the igniter connector, remove the mounting screw(s), and lift out the old igniter — handle by the ceramic base only.
  5. Install — Mount the new 1171306 igniter without touching the element, connect the 1188370 wiring kit, and confirm proper position relative to the burner.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace runs the inducer but never lights, then locks out
  • Igniter shows visible cracks or no longer glows
  • Open circuit / infinite resistance when ohmed out
  • Repeated ignition-failure fault codes on the control board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150LDBA0AGAA — OEM 1171306 + Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150LDBA0AGAA — OEM 1171306 + Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150LDBA0AGAA — OEM 1171306 + Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online