This is the genuine OEM hot surface igniter (part number 1171306) with its matching wiring kit (part number 1188370) for the ICP / Tempstar / Heil RGS150LDBA0AGAA gas furnace. On each call for heat, the control board energizes the igniter; it glows white-hot and ignites the gas at the burners. Hot surface igniters are brittle and wear out — micro-cracks, contamination from oils, and thermal cycling eventually cause an open element. The result is a furnace that runs the inducer and gas valve but never lights, locks out, and leaves you with no heat. Installing a fresh igniter and the correct wiring harness restores reliable ignition. Always handle the new igniter by its ceramic base — never touch the silicon-carbide element.
| Spec | Value |
|---|---|
| Part Numbers | 1171306 (igniter), 1188370 (wiring kit) |
| Type | Hot Surface Igniter |
| Element | Silicon carbide |
| Brand | ICP / Tempstar / Heil |
| Fits Model | RGS150LDBA0AGAA |
| Application | Gas furnace ignition |
Built for the ICP RGS150LDBA0AGAA and shared-platform Tempstar, Heil, Comfortmaker, and Day & Night gas furnaces using this igniter and harness. The included wiring kit (1188370) ensures a clean, correct connection to the furnace harness. Verify your model on the rating plate before ordering.