This OEM hot surface igniter assembly (part #1171306) with its matching wiring kit (#1188370) is the direct ignition source for the ICP / Tempstar / Heil RGS150HTCB0AAAA gas furnace. The igniter glows red-hot when energized at the start of a heat call, igniting the gas at the burner. Over thousands of cycles the silicon nitride element degrades, develops hairline cracks, or loses resistance — when it fails the furnace cannot light and you get no heat despite the blower and gas valve operating normally. Replacing the igniter with the factory wiring kit ensures the harness connector and terminals seat correctly and avoids intermittent no-light faults.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter (Silicon Nitride)
Brand ICP / Tempstar / Heil
Voltage 120V
Fitment OEM Direct Replacement

Compatibility

Engineered for the ICP/Tempstar/Heil RGS150HTCB0AAAA furnace and other models in the same gas furnace family that specify igniter 1171306. Always confirm against your unit's parts list.

Installation Guide

  1. Safety First — Shut off the gas and disconnect power at the furnace switch; verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/service panel.
  3. Document — Photograph the igniter mounting and wire routing before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift the old igniter out — handle the ceramic only, never the element.
  5. Install — Mount the new igniter, install the wiring kit connector, and route the harness clear of the burner flame path.
  6. Test — Restore gas and power, start a heat cycle, and confirm the igniter glows and burners light within seconds.

Signs You Need a Replacement

  • Furnace blower runs but burners never ignite (no heat).
  • Igniter does not glow or glows weakly/unevenly.
  • Visible cracks or white-spotting on the ceramic element.
  • Control board lockout after several failed ignition attempts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150HTCB0AAAA — Silicon Nitride with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150HTCB0AAAA — Silicon Nitride with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150HTCB0AAAA — Silicon Nitride with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online