OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM hot surface igniter (part 1171306) lights the burners on the gas-heat section of ICP/Tempstar/Heil RGS150HFCA0AAAA package units, and the matching wiring kit (part 1188370) provides the correct harness and connector for a clean replacement. On a call for heat the control board sends voltage to the igniter, which glows white-hot and ignites the gas at the burners. Hot surface igniters are brittle and degrade with every heating cycle. A cracked or worn igniter is the single most common cause of no-heat furnace failures — the inducer and gas valve sequence, but the burners never light. Replacing the igniter (and refreshing the wiring connection) restores dependable ignition.
| Spec | Value |
|---|---|
| Part Numbers | 1171306 (igniter), 1188370 (wiring kit) |
| Type | Hot Surface Igniter |
| Brand | ICP (Tempstar / Heil) |
| Application | Furnace / gas-heat burner ignition |
| Fitment | OEM — direct replacement |
Designed for the ICP RGS150HFCA0AAAA package unit and other RGS150-series models using the same hot surface ignition system. The included wiring kit ensures a correct plug-in connection without splicing.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.