Overview

This OEM hot surface igniter lights the burners on your ICP RGS150HEAA0AKAA gas furnace. On a heat call the control board sends 120V to the igniter, which glows orange-hot within seconds and ignites the gas as it crosses the burners. The kit pairs the igniter (OEM 1171306) with the matching wiring harness kit (OEM 1188370) so you get a complete, plug-in replacement. Hot surface igniters are brittle silicon-carbide or silicon-nitride elements that degrade with every cycle and crack easily — the single most common no-heat failure on modern furnaces. Never touch the element with bare fingers; skin oils create hot spots that shorten its life.

Specifications

Spec Value
OEM Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil / Comfortmaker)
Voltage 120V
Includes Igniter + wiring harness kit

Compatibility

A direct OEM fit for the ICP RGS150HEAA0AKAA and shared ICP-family furnaces sold under Tempstar, Heil, Comfortmaker, and Arcoaire. Confirm the igniter style and connector against your original before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment door.
  3. Document — Photograph the igniter mounting and connector routing.
  4. Remove — Unplug the harness, remove the mounting screw, and lift the cracked igniter out by its ceramic base only.
  5. Install — Seat the new igniter (handle by the base, never the element), secure the screw, and connect the new wiring kit.
  6. Test — Restore power and watch for a full glow and clean burner light-off on the next heat call.

Signs You Need a Replacement

  • Furnace blower runs but burners never light
  • Igniter shows a visible crack or no longer glows
  • Furnace locks out after several failed ignition attempts
  • Resistance reads open or far out of spec on a multimeter

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150HEAA0AKAA — 120V with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150HEAA0AKAA — 120V with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150HEAA0AKAA — 120V with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online