This OEM hot surface igniter (HSI) is the component that lights the burners on your ICP/Tempstar/Heil RGS150HDBA0AAAA gas furnace. On each heating call the control board sends line voltage to the igniter, which glows to roughly 2,000°F and ignites the gas as it leaves the burners. This listing covers the igniter (OEM 1171306) along with the matching igniter wiring kit (OEM 1188370) for a clean, complete replacement. Hot surface igniters are brittle ceramic elements and are the single most common no-heat failure — they crack from thermal cycling, contamination from oily fingerprints, or simple age. A furnace that runs the inducer and blower but never lights, or that short-cycles on ignition lockout, is the classic symptom of a failed igniter.

Specifications

Spec Value
Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Element Ceramic / Silicon Carbide
Application Gas Furnace Ignition

Compatibility

Designed for the ICP/Tempstar/Heil RGS150HDBA0AAAA gas furnace and other ICP-family furnaces using this igniter assembly. Confirm igniter mounting bracket and plug style against your existing part.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the furnace switch, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner-compartment door.
  3. Document — Photograph the igniter position and wiring routing before disconnecting.
  4. Remove — Unplug the igniter harness and remove the mounting screw; handle the old element by its base only.
  5. Install — Mount the new igniter without touching the ceramic element, then connect the new wiring kit per your photo.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm the igniter glows and burners light.

Signs You Need a Replacement

  • Furnace inducer and blower run but burners never ignite
  • Visible crack or break in the ceramic element
  • Igniter does not glow on a heat call
  • Repeated ignition-lockout / short-cycling on no heat

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS150HDBA0AAAA — Furnace Ignitor Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS150HDBA0AAAA — Furnace Ignitor Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS150HDBA0AAAA — Furnace Ignitor Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online