Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS121LTBB0AAAA — OEM 1171306 with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS121LTBB0AAAA — OEM 1171306 with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (HSI) ignites the burners on your ICP/Heil/Tempstar RGS121LTBB0AAAA gas furnace. On a call for heat, the control board energizes the igniter, which glows white-hot and lights the burner gas. When an igniter cracks, develops hairline fractures, or burns out, the furnace will cycle on the inducer and gas valve but never establish a flame — leaving you with no heat and often a lockout fault code. This kit includes OEM igniter part 1171306 and igniter wiring kit 1188370 for a complete, plug-and-play replacement.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Fits Model RGS121LTBB0AAAA
Fit OEM
Application Gas Furnace

Compatibility

Engineered for the ICP family RGS121LTBB0AAAA gas furnace and shared-platform Heil, Tempstar, and Comfortmaker units that use igniter 1171306. Always confirm your existing igniter part number before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power at the furnace switch; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter bracket position and wiring before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift the old igniter out without touching the silicon nitride element.
  5. Install — Seat the new igniter in the same position, secure the screw, and connect the new wiring kit per your photo.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and the burners light cleanly.

Signs You Need a Replacement

  • Furnace runs the inducer but never lights the burners
  • Visible cracks, chips, or white spots on the igniter element
  • Repeated ignition-failure lockouts after several retries
  • No glow visible through the inspection port during a heat call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121LTBB0AAAA — OEM 1171306 with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121LTBB0AAAA — OEM 1171306 with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121LTBB0AAAA — OEM 1171306 with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.