This OEM hot surface igniter (part #1171306) and matching igniter wiring kit (part #1188370) are the factory-specified ignition components for the ICP / Heil / Tempstar RGS121LRAB0AAAA gas furnace. The igniter is a 120V hot surface element that glows red-hot to light the main burners on each call for heat. When the igniter cracks, develops hairline fractures, or its silicon nitride element degrades from thousands of heating cycles, the furnace will lock out and fail to fire. Common failure symptoms include the furnace running the inducer and blower but never igniting, repeated ignition lockouts after three tries, or a visibly broken/whitened element. The included wiring kit ensures a clean, corrosion-free electrical connection to the control board.

Specifications

Spec Value
OEM Part Number 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Voltage 120V
Element Silicon Nitride
Fits Model RGS121LRAB0AAAA

Compatibility

Engineered as a direct-fit replacement for the ICP/Heil/Tempstar RGS121LRAB0AAAA furnace and other compatible International Comfort Products gas furnaces using the same ignition platform. Always confirm your model number before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter bracket and wiring before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift out the old igniter. Never touch the new element with bare fingers — skin oils cause premature failure.
  5. Install — Mount the new igniter, install the wiring kit, and reconnect per your photo.
  6. Test — Restore power and watch a full ignition cycle to confirm the burners light.

Signs You Need a Replacement

  • Furnace locks out after several failed ignition attempts
  • Inducer and blower run but burners never light
  • Igniter shows cracks, white spots, or no longer glows
  • No continuity across the igniter terminals

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121LRAB0AAAA — 120V Furnace Ignitor Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121LRAB0AAAA — 120V Furnace Ignitor Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121LRAB0AAAA — 120V Furnace Ignitor Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.