Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS121LDAB0AAAA — OEM Ignitor with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS121LDAB0AAAA — OEM Ignitor with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part 1171306) with matching wiring kit (part 1188370) lights the burners in the ICP / Tempstar / Heil RGS121LDAB0AAAA gas furnace. On each heat call the control board sends voltage to the igniter, which glows red-hot to ignite the gas as it flows across the burners. Hot surface igniters are fragile and degrade with every cycle — the silicon nitride or carbide element thins, develops hairline cracks, and eventually fails open, leaving the furnace unable to light. Symptoms include no heat, a furnace that clicks but won't ignite, or a unit that locks out after several failed ignition attempts. The included wiring kit ensures a clean, factory-correct connection.

Specifications

Spec Value
OEM Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Includes Igniter + Wiring Harness Kit
Application Gas Furnace Burner Ignition

Compatibility

Built for the ICP RGS121LDAB0AAAA furnace and RGS-series models using the same ignition system. Match the igniter mounting profile and connector to your existing part before installing.

Installation Guide

  1. Safety First — Disconnect electrical power and verify zero voltage with a multimeter; shut off the gas supply.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photograph the igniter position and wiring routing before disconnecting.
  4. Remove — Unplug the igniter harness and remove the mounting screw, handling the element only by its ceramic base — never touch the glow tip.
  5. Install — Mount the new igniter, attach the wiring kit, and route the harness per your photo.
  6. Test — Restore gas and power, initiate a heat call, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • No heat — furnace runs but burners never ignite
  • Visible cracks or breaks in the igniter element
  • Furnace locks out after repeated failed ignition tries
  • Igniter no longer glows during a heat call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121LDAB0AAAA — OEM Ignitor with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121LDAB0AAAA — OEM Ignitor with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121LDAB0AAAA — OEM Ignitor with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online