Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS121HSAA0AAAA — Silicon Carbide HSI with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS121HSAA0AAAA — Silicon Carbide HSI with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The hot surface igniter (HSI) ignites the burners on your ICP RGS121HSAA0AAAA gas furnace. When the thermostat calls for heat, the control board sends 120V to the igniter, which glows red-hot within seconds to light the gas at the burner. This OEM kit includes the silicon carbide igniter (OEM part 1171306) and the matching igniter wiring kit (OEM part 1188370) for a complete, code-correct replacement. The igniter element is brittle and degrades with every heating cycle until it finally cracks or can no longer reach ignition temperature — making it one of the most common causes of a no-heat furnace.

Specifications

Spec Value
Igniter Part Number 1171306
Wiring Kit Part Number 1188370
Type Hot Surface Igniter (HSI)
Brand ICP / Tempstar / Heil
Voltage 120V
Fitment OEM
Model RGS121HSAA0AAAA

Compatibility

Direct fit for the ICP / Tempstar / Heil RGS121HSAA0AAAA gas furnace and other units in the ICP RGS family of induced-draft furnaces. Always confirm your OEM part number against the unit before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, verify zero voltage with a multimeter, and shut off the gas supply.
  2. Access — Remove the burner compartment service panel.
  3. Document — Photo the igniter mounting position and wiring before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and withdraw the old igniter. Never touch the new element with bare fingers — skin oils create hot spots that shorten its life.
  5. Install — Mount the new igniter in the correct burner flame path, install the wiring kit, and reconnect per your photo.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and the burners light within a few seconds.

Signs You Need a Replacement

  • Furnace blows cold air or produces no heat
  • Igniter does not glow or glows weakly on a heat call
  • Visible cracks or white/discolored spots on the element
  • Repeated ignition lockouts after failed attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121HSAA0AAAA — Silicon Carbide HSI with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121HSAA0AAAA — Silicon Carbide HSI with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121HSAA0AAAA — Silicon Carbide HSI with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.