Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS121HRBB0AAAA — with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS121HRBB0AAAA — with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

Genuine OEM hot surface igniter (part #1171306) with matching igniter wiring kit (part #1188370) for the ICP / Heil / Tempstar RGS121HRBB0AAAA gas furnace. The hot surface igniter glows red-hot when energized to ignite the burner gas at the start of each heating cycle. The included wiring kit provides the correct harness and connector to ensure a clean, reliable electrical connection. Hot surface igniters are brittle and degrade over time — a cracked or worn element is one of the most common reasons a furnace blows cold air or fails to light on a call for heat.

Specifications

Spec Value
Igniter Part Number 1171306 (Ignitor)
Wiring Kit Part Number 1188370 (Wiring Kit Igniter)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Application Gas Furnace Burner Ignition
Fit OEM

Compatibility

Designed for the ICP-family RGS121HRBB0AAAA furnace and related models using the same hot surface igniter. Confirm the igniter shape and mount against OEM part 1171306 before ordering.

Installation Guide

  1. Safety First — Disconnect power and shut off gas; verify zero voltage with a multimeter.
  2. Access — Remove the burner compartment door to expose the igniter.
  3. Document — Photograph the igniter position and wiring routing before disconnecting.
  4. Remove — Unplug the igniter harness, unscrew the mounting bracket, and remove the old igniter without touching the element with bare hands.
  5. Install — Mount the new igniter, connect the new wiring kit, and verify the element sits correctly in the burner flame path per your photo.
  6. Test — Restore gas and power, then watch a full ignition cycle to confirm the igniter glows and the burner lights.

Signs You Need a Replacement

  • Furnace blows cold air or fails to ignite on a heat call
  • Visibly cracked, chipped, or discolored igniter element
  • No glow during the ignition sequence
  • Repeated lockouts or short cycling on startup

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121HRBB0AAAA — with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121HRBB0AAAA — with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121HRBB0AAAA — with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.