Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Hot Surface Igniter for RGS121HRBA0AAAA — with Wiring Kit | Ships Today
ICP

ICP Hot Surface Igniter for RGS121HRBA0AAAA — with Wiring Kit | Ships Today

SKU: 1171306 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM hot surface igniter (part number 1171306) lights the burners on your ICP / Tempstar / Heil RGS121HRBA0AAAA gas furnace. On a call for heat the control board powers the igniter, which glows red-hot to ignite the gas as it flows across the burners. The matching wiring kit (1188370) is included to ensure a clean, factory-spec electrical connection. Hot surface igniters are brittle and wear out over time — they crack, develop hairline fractures, or fail to reach ignition temperature, leaving you with no heat, a furnace that clicks but never lights, or a unit that locks out after several failed ignition attempts.

Specifications

Spec Value
Part Numbers 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP (Tempstar / Heil)
Includes Igniter + igniter wiring kit
Fits Model RGS121HRBA0AAAA
Fitment OEM direct replacement

Compatibility

Engineered for the ICP / Tempstar / Heil RGS121HRBA0AAAA gas furnace. The included wiring kit (1188370) matches the OEM connector for this model. Verify your existing igniter part number (1171306) before ordering for a guaranteed fit.

Installation Guide

  1. Safety First — Turn off gas and disconnect power. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace burner/service panel to reach the igniter near the burner assembly.
  3. Document — Photograph the igniter mounting position and wiring routing before removal.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and carefully withdraw the old igniter. Never touch the new element with bare fingers — skin oils cause early failure.
  5. Install — Seat the new igniter, secure the mounting screw, and connect using the included wiring kit per your photos.
  6. Test — Restore gas and power, call for heat, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • Furnace will not light or produces no heat
  • Visible cracks or breaks in the igniter element
  • Igniter no longer glows during a heat call
  • Furnace locks out after repeated failed ignition attempts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121HRBA0AAAA — with Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121HRBA0AAAA — with Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121HRBA0AAAA — with Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart