Overview

This OEM hot surface igniter (HSI) is the direct-fit ignition component for the ICP Tempstar / Heil RGS121HECB0AAA gas furnace. The igniter (OEM part 1171306) is a silicon-carbide or silicon-nitride heating element that glows to roughly 2,500°F to ignite the burner gas on each heating call. Because it is the single most cycled part in the furnace, it is also the most common failure point. This listing includes the matching igniter wiring kit (OEM part 1188370) so you have the harness and connector needed for a clean replacement. Typical failure symptoms include a furnace that runs the inducer and opens the gas valve but never lights, no visible glow at the igniter, a cracked or chipped element, or a hairline fracture that reads open on a multimeter.

Specifications

Spec Value
Part Number 1171306 (igniter), 1188370 (wiring kit)
Type Hot Surface Igniter
Brand ICP / Tempstar / Heil
Fits Model RGS121HECB0AAA
Application Gas furnace burner ignition
Includes Igniter + igniter wiring kit

Compatibility

Engineered for the ICP family RGS121HECB0AAA gas furnace and shared Tempstar, Heil, Comfortmaker, and Day & Night models that use the same ignition platform. Always confirm against your unit's parts breakdown before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter before proceeding.
  2. Access — Remove the lower burner/service panel.
  3. Document — Photograph the igniter bracket position and wiring before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and lift the old igniter free without touching the element with bare fingers.
  5. Install — Mount the new igniter at the same depth and angle, install the wiring kit, and reconnect per your photo.
  6. Test — Restore power and run a heat cycle; confirm the igniter glows and the burners light within a few seconds.

Signs You Need a Replacement

  • Inducer runs and gas valve opens but burners never ignite
  • No orange/white glow visible at the igniter during a heat call
  • Visible cracks, chips, or white spots on the element
  • Open-circuit or out-of-range resistance reading on a multimeter

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121HECB0AAA Gas Furnace — Includes Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121HECB0AAA Gas Furnace — Includes Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121HECB0AAA Gas Furnace — Includes Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.