This OEM hot surface igniter (OEM 1171306) with its matching igniter wiring kit (OEM 1188370) is the ignition component for the ICP / Heil / Tempstar RGS121HDCB0AAA gas furnace. On each heat call, the control board sends voltage to the igniter, which glows white-hot and lights the burner gas. Hot surface igniters are made of a brittle silicon-carbide or silicon-nitride element that degrades with every thermal cycle and eventually cracks or burns open. When it fails, the burners never light, the furnace locks out, and you get cold air or no heat at all. Replacing the igniter — and refreshing the wiring connector with the included kit — restores fast, dependable ignition. Never touch the element with bare fingers; skin oils create hot spots that shorten its life.

Specifications

Spec Value
OEM Part Numbers 1171306 (Igniter), 1188370 (Wiring Kit)
Type Hot Surface Igniter
Brand ICP / Heil / Tempstar
Includes Igniter + Wiring Harness Kit
Application Gas Furnace Ignition
Fitment OEM Replacement

Compatibility

Direct OEM replacement for the ICP / Heil / Tempstar RGS121HDCB0AAA gas furnace and other ICP-family models using this igniter platform. Confirm the igniter element shape and connector against your existing part before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the burner-compartment service panel.
  3. Document — Photograph the igniter position, bracket, and wiring before disconnecting.
  4. Remove — Unplug the igniter harness, remove the mounting screw, and carefully withdraw the old igniter without bumping the element.
  5. Install — Mount the new igniter (handle by the ceramic base only), install the wiring kit, and reconnect per your photos.
  6. Test — Restore gas and power, run a heat cycle, and confirm the igniter glows and the burners light promptly.

Signs You Need a Replacement

  • No heat — burners never ignite on a heat call.
  • Furnace clicks and locks out, then retries repeatedly.
  • Igniter no longer glows, or shows visible cracks/breaks.
  • Intermittent ignition, especially on cold starts.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Igniter fit my ICP RGS121HDCB0AAA — With Wiring Kit | Ships Today?
Yes. This is the factory-specified OEM igniter for the ICP RGS121HDCB0AAA — With Wiring Kit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the igniter on my ICP RGS121HDCB0AAA — With Wiring Kit | Ships Today?
Difficulty: Medium (20–30 min)
Step 1: Turn off power and gas. Step 2: Open furnace panel. Step 3: Locate igniter near burners. Step 4: Disconnect two-wire plug. Step 5: Remove mounting screw. Step 6: Install new igniter — do NOT touch element with fingers. Step 7: Reconnect, close panel, restore power/gas.
My furnace won’t ignite. What part is bad?
Furnace won’t ignite after the draft inducer runs = failed igniter. The hot surface igniter should glow bright orange within 60 seconds. No glow = cracked/burned out. Weak glow = degrading. Average lifespan: 3–7 years. Replacement: $15–$40 DIY.
Is this igniter compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP igniter?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online